<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-11 04-50-17
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 53 dBuV R-PCE
Pilot RDS Phase Difference
6.0 kHz 2.6 kHz -86 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
9 kHz 38 kHz 18524 0,1026
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,9 dBr -1,37 dBr -0,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 4:50, 11.10.2025
RT
"Pisnicky ktere nestarnou "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 38 kHz MIN: 9 kHz % above 77 kHz: 0,1026 Acquired: 2025/10/11 4:50:14 Total samples: 18524 Equivalent time: 0:15:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,9 dBr MIN: -1,9 dBr AVE: -1,37 dBr % above 0,2 dBr: 0,0 Last value: -1,2 dBr (2025/10/11 4:50:14) 04:36 04:38 04:40 04:42 04:44 04:46 04:48 04:50 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality